Kentec T11020M2 Fire Control Panels

£251.95 Inc VAT

In stock

  • Construction : 1.2 mm mild sheet steel
  • Finish : Epoxy powder coated
  • Colour – lid & box : BS 00 A 05 grey – fine texture
  • Colour – control plate & labels : RAL 7047 light grey – satin
  • Supply voltage : 230 VAC (+10%/-15%)
  • Mains supply fuse : 1.6 A 250V
  • Power supply DC rating : 24V 3A
  • Maximum battery size : 7Ah 12V (2 per panel)
  • Fault contact rating : 30 VDC 1A
  • Local fire contact rating : 30 VDC 1A
  • Fire contact rating : 30 VDC 1A
  • Sounder output rating : 0.5A per output (Max 1.6A over all outputs)
  • Detection zone current : 1.6 mA
  • Detection zone EOL resistor : 6K8 5%
  • Active EOL : K14606K (optional)
  • Sounder output EOL resistor : 10K 5%
  • Cable capacity : 2.5 mm©
  • Operating temperature : -5°C a +50°C
  • Operating humidity : < 95% (non condensing)
  • Dimension : 385 mm x 310 mm x 90 mm
  • Standby current 2 zones : 0.065 A
  • Standby current 4 zones : 0.075 A
  • Standby current 8 zones : 0.093 A
  • Alarm current 2 zones : 0.15 A
  • Alarm current 4 zones : 0.30 A
  • Alarm current 8 zones : 0.63 A
  • 3 year warranty
  • Kentec T11020M2 Fire Control Panels user manuals
  • Kentec T11020M2 Fire Control Panels data sheet
Compare
SKU: T11020M2 Category: Tags: , , , ,

£251.95 Inc VAT

Name Range Discount
Qty 4 - 9 1 %
Qty 10 - 19 1.5 %
Qty 20 - 99 2 %
Qty 100 - 1000 4 %

Description

Kentec T11020M2 Fire Control Panels

this product consists of a series of conventional fire detection alarm system panels designed in accordance with European standards BS EN54-2 and BS EN54-4 Fire Detection and Fire Alarm systems – Control and Indicating Equipment.
The range consists of 2, 4 and 8 zone fire detection alarm system panel.
Sigma T11 range in which detectors, call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.
Wiring sounders to the detection circuit eliminates the need to install sounder circuit cables and also offers the ability to provide zoned or two stage sounder operation.

Notes : For 2-wire T series panels, compatible detectors and call points must be used. All sounders must be polarised.

All fire detection alarm system panel have an integral, mains powered battery charger and power supply designed in accordance with the requirements of BS EN54-4.

Main FEATURES

1  Fully certified to BS EN54-2 and BS EN54-4
2  2-wire Versions in 2, 4 or 8 zones
3 Compatible for use on BS5839: Part 1: 2002 installations
4 2-wire repeaters and ancillary boards
5 Fully programmable using simple menu options
6 Adjustable sounder delay time
7 Sounder configuration options
9 Zonal sounder delay call points only
10 Coincidence input selection
11 I.S Barrier selection by zone
12 Short circuit fire by zone
13 Non latching zones
14 Silent zones
15 Zone input delay
16 General panel configuration
17 Simple, single board construction
18 Installer friendly
19 Compatible with wide range of fire detection devices
20 3 Amp power supply
21  Auxiliary power output

for more similar product visit our site