No products in the cart.
-
Hochiki YBN-R/3(WHI) Addressable/Analogue Detection
- Electronics free
- Slim profile – only 8 mm
- Rugged stainless steel wiring contacts
- Facility for remote indicator
- 3 year warranty
- Hochiki YBN-R/3(WHI) Addressable/Analogue Detection instruction
- Hochiki YBN-R/3(WHI) Addressable/Analogue Detection data sheet
£1.89 Inc VAT -
Hochiki ALN-EN(WHT) Addressable/Analogue Detection
- Removable, High Performance chamber
- Twin LEDs allow 360deg viewing – green when polling, turn red in fire
- Electronically addressed
- Pulsing/non-pulsing controlled from panel
- EN54-7
- 3 year warranty
- Hochiki ALN-EN(WHT) Addressable/Analogue Detection data sheet
£29.02 Inc VAT -
Apollo SA7100-100APO Addressable/Analogue Detection
- Intelligent Auto-Aligning Beam Detector
- Operating range 8-50 Metres
- Compatible with Discovery andXP95 protocols
- Drift compensation
- Integral laser and auto- align enable quicker installation
- Alignment compensation for building movement
- Low-level systemcontroller with LCD display and user friendly interface
- EN54-12/17
- 10 year warranty
- Apollo SA7100-100APO Addressable/Analogue Detection data sheet
- Apollo SA7100-100APO Addressable/Analogue Detection installation guide
£421.93 Inc VAT -
Apollo SA5900-908APO Pull Stations/Manual Call Points
- Resettable operating element
- Easy access, front rest mechanism
- E-Z fit connector system for installation
- Front facing LED
- Continuity link for cable insulation testing
- Suitable for semi flush or surface mounting
- EN54-11 & EN54-17 Certified
- 10 year warranty
- Apollo SA5900-908APO Pull Stations/Manual Call Points installation guide
£31.49 Inc VAT -
Hochiki YBO-R/3 RED Addressable/Analogue Detection
- Colour matches with CHQ-WS2 Wall
Sounder and CHQ-WSB Wall Sounder
Beacon - Detects short circuits on loop
- Status LED
- Connection of up to 127 per loop
- Bayonet slot, low insertion force for
detectors - Quick connection via square cable clamps
- Hochiki YBO-R/3 RED Addressable/Analogue Detection data sheet
£1.90 Inc VAT - Colour matches with CHQ-WS2 Wall
-
Hochiki YBO-BSB2(WHT)/WL Horn (Sounder)/Strobes (Beacons)
- Loop Powered with Single Loop Address – addressed automatically by Control Panel or via the TCH-B200 Hand Held Programmer
- Approved to EN54-23 – Category ‘O’
- Variable Sound Output 50-98dB(A)
- Fits Hochiki Standard or Isolator Base and supports ESP Sensors, Addressable Beacons and Addressable Remote Indicator
- 51 User-Selectable Tones (all tones EN54-3 compatible)
- Beacon and Sounder can be controlled independently *check panel compatibility*
- Auto-Shutdown feature prevents noise-pollution *check panel compatibility*
- 3 year warranty
- Hochiki YBO-BSB2(WHT)/WL Horn (Sounder)/Strobes (Beacons) data sheet
£48.05 Inc VAT -
Apollo 38531-771 Fire Accessory Products
- Simplifies and speeds up installation and commissioning
- Uses patented proven technology
- Address remains the same, no matter how often detectors are replaced
- Flexibility to create any address
- 3 year warranty
- Apollo 38531-771 Fire Accessory Products data sheet
£0.18 Inc VAT -
Apollo 45681-278 Horns (Sounders)
- Two tones
- Two volume ranges 55-75dB(A) and 75-91dB(A)
- Individual and group addressing
- Unique acoustic self-test
- 3 year warranty
- Apollo 45681-278 Horns (Sounders) installation guide
- Apollo 45681-278 Horns (Sounders) data sheet
£31.35 Inc VAT -
Apollo 45681-292 Horns (Sounders)
- for use with base sounders
- 3 year warranty
- Apollo 45681-292 Horns (Sounders) installation guide
- Apollo 45681-292 Horns (Sounders) data sheet
£2.75 Inc VAT -
System Sensor B501AP Addressable/Analogue Detection
- Quick and secure detector plug-in
- Connect to Pertronic analogue addressable loop (AA Loop)
- Screw terminals for AA loop (+ and –) and remote annunciator
- SEMS screws provide easy wiring connection
- Suit cable from 0.5 mm² to 2.5 mm²
- Optional temper-resist feature
- System Sensor B501AP Addressable/Analogue Detection installation guide
- System Sensor B501AP Addressable/Analogue Detection data sheet
£4.75 Inc VAT -
Apollo 45681-331 Horns (Sounders)
- Two volume ranges 55-75dB(A) and 75-91dB(A)
- Visual indicator flash rate of once per second
- Synchronisation of ‘alert’ and ‘evacuate’ tones
- Synchronisation of visual indicator flash
- Individual and group addressing
- Unique acoustic and visual indicator self-
- Apollo 45681-331 Horns (Sounders) installation guide
- Apollo 45681-331 Horns (Sounders)data sheet
£50.75 Inc VAT -
Vimpex VMIS-R Fire Accessory Products
- Double-pole
- 230Vac 4A
- Keyswitch isolation
- Green LED
- 1 year warranty
- Vimpex VMIS-R Fire Accessory Products data sheet
£32.11 Inc VAT -
Elmdene G2405N-C Power Management
- 24Vdc Switch Mode PSU (27.6V) 5Amp to load 0.5A battery charging
- Multi LED status indication
- Fit up to 2x7Ah batteries
- ‘C’ Box: 275h x 330w x 80d – Hinge lid
- 3 Year Warranty
- Elmdene G2405N-C Power Management data sheet
£92.41 Inc VAT -
Xpander XPA-CB-12034-APO Wireless Detectors
- Performs well in both black and white smoke environments
- Built in transient rejection and drift compensation
- Bi-directional (monitored) radio communications
- XPERT card addressing system
- 5 year battery life (using standard AA alkaline batteries)
- Certified to EN54-25
- 10 year warranty
- Xpander XPA-CB-12034-APO Wireless Detectors data sheet
£255.04 Inc VAT -
Alarmsense 55000-190 Conventional Detection
- 57°C Rate of rise heat detector
- Can be used for applications where smoke detectors are unsuitable
- Ideal for environments that are dirty or smoky under natural conditions
- Wide operating voltage
- EN54-5
- 3 year warranty
- Alarmsense 55000-190 Conventional Detection data sheet
£14.61 Inc VAT -
KAC M1A-R470SF-STCK-01 Pull Stations/Manual Call Points
- Surface mount
- Flexible element
- Unique ‘Plug & Play’ installation concept
- Total ‘Flex-Ability’ in the choice of operating element
- Anti-Tamper facility
- Enhanced aesthetics
- Fully approved to the latest standards
- Backward compatibility
- CPD Approved
- 470Ohm resistor
- EN54-11
- 3 year warranty
- KAC M1A-R470SF-STCK-01 Pull Stations/Manual Call Points data sheet
£6.37 Inc VAT -
Apollo 55100-001APO Pull Stations/Manual Call Points
- Conventional Manual Call Point without LED – Red
- Plug and play’ terminal connections for fast wiring
- Resettable element
- Apollo 55100-001APO Pull Stations/Manual Call Points installation guide
- Apollo 55100-001APO Pull Stations/Manual Call Points data sheet
£12.39 Inc VAT -
Apollo 45681-702APO Horns (Sounders)
- 93dBA
- 15 evacuation tones 15 secondary or alert tones
- Software-defined group addressing
- Alarm switching by individual device, by group or of all devices on loop
- Built in isolator with status information
- EWN53-3/17
- 3 year warranty
- installation guide
- Apollo 45681-702APO Horns (Sounders) user manual
- Apollo 45681-702APO Horns (Sounders) data sheet
£35.66 Inc VAT -
Elmdene STX2405-C Power Management
- Elmdene’s new STX range of high quality, cost effective EN54-4, 3rd party certified power supplies are designed specifically for Fire applications
- Available in 24V dc 1A, 2A, 5A and 10A power variants in a choice of enclosures they are capable of providin
- Certified by UL to EN54-4:1997 +A1 +A2.
- Up to 5A current to load at 27.6V dc nominal regulated output.
- Charging capability to support 7 or 17/18Ah batteries.
- Electronic overload protection shuts down output until overload or short circuit is removed.
- Battery Monitor detects battery missing, low battery, short-circuit or reverse connection or circuit
impedance (Ri) in excess of 500mΩ caused by connector or wiring corrosion within 4hours. - Battery charging circuit is energised only when a battery is correctly connected and the battery voltage
is greater than 14 V. - No loss of output during automatic connection of battery to load on loss of mains.
- Deep discharge protection disconnects battery from load when battery voltage falls below 21 V.
- Diagnostic indicator LED (Orange) (Internal).
- Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains
failure. - Mains indicator LED (Green) showing mains present Indicators check at start-up.
- Optional RS232 serial interface for fault reporting and diagnostics.
- Elmdene STX2405-C Power Management data sheet
£126.98 Inc VAT -
C-Tec CFP708-4 Fire Control Panels
- 8 Zone circuits
- Plastic lid and base
- 380 x 235 x 96mm
- 1 year warranty
- C-Tec CFP708-4 Fire Control Panels user manual
- C-Tec CFP708-4 Fire Control Panels data sheet
£183.38 Inc VAT -
Fike 505-0004 Fire Control Panels
- 331 x 331 x 99mm
- Dimensions: Width x Height: 331mm x 331mm
- Depth: 99mm
- Operating Temperature: +5°C to +40°C
- Mains Supply Range: 230VAC, +10%, -15%, 50/60Hz
- Standby Battery Requirement: 2 x 3.3Ah 12V Sealed Lead Acid
- Number of Zones: 4/8
- Max Zone Length: 500 Metres
- Zone Loading: 160 DLU (32 Devices Max)
- Zone Operating Voltage: Nominal: 29.9VDC
- Max Zone Current: 250mA
- LCD Display: 4 Lines of 20 Characters
- Zone Labels: 12 Characters
- 2 year warranty
- Fike 505-0004 Fire Control Panels data sheet
£363.75 Inc VAT -
Advanced Electronics MXP-503 Fire Control Panels
- Standard network card
- Large Ad-NeT+ 200 Panel Network
- Up to 1.5Km between Control Panels
- Windows based PC setup
- Network Systems share up to 1000 zones
- Network Analysis from Contol Panel
- 3 year warranty
- Advanced Electronics MXP-503 Fire Control Panels data sheet
£263.25 Inc VAT -
Advanced Electronics MXP-003 Fire Control Panels
- Standard network card
- 3 year warranty
- Advanced Electronics MXP-003 Fire Control Panels data sheet
£263.25 Inc VAT -
Safety Technology Int. STI-13110FR Fire Protective Covers
- Helps prevent malicious or accidental damage to electrical switches and call points
- Includes weather gaskets making the unit weatherproof
- For use in and outdoor
- 3 year warranty
£66.92 Inc VAT -
Alarmsense 55000-193 Conventional Detection
- 90°C Static heat detector
- Can be used for applications where smoke detectors are unsuitable
- Ideal for environments that are dirty or smoky under natural conditions
- Wide operating voltage
- EN54-5
- 3 year warranty
- Alarmsense 55000-193 Conventional Detection data sheet
- Alarmsense 55000-193 Conventional Detection user guide
£15.02 Inc VAT -
Apollo 55000-802 Addressable/Analogue Detection
- Loop-powered
- Polarity sensitive
- Up to 20 detectors can be installed between isolators
- Allows fully isolated spurs
- EN54-17
- 3 year warranty
- Apollo 55000-802 Addressable/Analogue Detection installation guide
- Apollo 55000-802 Addressable/Analogue Detection data sheet
£47.44 Inc VAT -
KAC K20SRS-01 Pull Stations/Manual Call Points
- Key removable in both positions
- Indoor
- Plain
- 3 Year warranty
- KAC K20SRS-01 Pull Stations/Manual Call Points cover data sheet
£17.48 Inc VAT