C-Tec EVC302GS Voice Evacuation Alarms
- Approvals/certifications Facilitate compliance with BS5839-9 when correctly installed
- Supply/operating voltage 11V DC derived from a compatible SigTEL Master Controller (drops to 6 V DC when in use).
- Quiescent current 3m AA ctivation current 25mA (current draw when intercom is in use).
- Open collector outputsO/P +Ve & O/P –Ve (closes when outstation is active, typically used to trigger a third party CCTV camera, opto-isolated, normally open, max. 24 V DC, 3 mA).
- Indicators Red call in progress LED Controls External ‘Push to Call or Answer’ button (Off Hook); Internal Loudspeaker volume control; Engineer’s “On Hook” and “Off Hook” pins.
- Expansion connections AFILS +Ve & AFILS –Ve (typically connected to the line-level input of an optional induction loop amplifier): Off-Hook and -Ve (can be optionally connected to an NC951 accessible toilet alarm kit (see instructions for details).
- Product dimensions (mm)160 W x 240 H x 53 D mm.Construction & finish Green steel.
- IP Rating IP20.
- Weight 1.3 kg.
- Operating conditions/temperature -5ºC to +40ºC. Max relative humidity: 95%.
- 1 year warranty
- C-Tec EVC302GS Voice Evacuation Alarms data sheet
£153.74 Inc VAT -
C-Tec ECU-8 Voice Evacuation Alarms
- Approvals/certifications Facilitate compliance with BS5839-9 when correctly installed
- Mains supply 230V 50/60Hz.
- Mains rated current500mA.
- Internal power supply 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).
- Total output current limited to1.5A @ 230Vac Quiescent current100mA (controller with fault buzzer sounding) plus 1mA per Type A outstation and 3.2mA per Type B outstation.
- Max battery size and type2 x 12V 7Ah VRLA connected in series.
- No. of lines8.Auxiliary relay changeover fault relay (failsafe). 30V 1A max
- Open collector outputs(OP1): Activates when the ECU is ringing; (OP2) Activates when there is an active accessible toilet alarm call; (OP3) Closes when the handset is off-hook and remains active for 2 mins after it is replaced. 24V, 50mA max.
- Other outputs +24 V.
- Typically used to supply power to equipment connected to the ECU’s open-collector outputs (relays, etc). Engineer (AL3) functions Engineer mode and reset buttons (internal).
- Indicators 128 x 64 pixel LCD display; Disablement; System fault; PSU fault; General fault; Power on.
- ControlsSilence Buzzer.
- Other controls are available but are not applicable as no handset is provided on this unit.
- Product dimensions (mm)410 W x 250 H x 80 D mm (base); 439 W x 274 H x 7 D mm (lid).
- Construction & finish metal lid and base, RAL7035 grey texture.
- IP Rating IP20.
- Weight 3.1kg (without batteries).
- Operating conditions/temperature-5ºC to +40ºC. Max relative humidity: 95%.
- 1 year warranty
- C-Tec ECU-8 Voice Evacuation Alarms data sheet
£1,007.53 Inc VAT -
C-Tec EVC385 Voice Evacuation Alarms
- Compatibility Suitable for use with SigTEL ECU-4, ECU-8, ECU-8S and ECU-8NT controllers).
- Product dimensions (mm) Front face when in situ measures 456 W x 293 H mm.
- Actual depth of bezel is 31mm.
- Hole required for semi-flush mounting is 412 W x 255 H x 50 D mm.
- Construction & finish Mild steel.
- Weight 0.50kg.
- Bezel for semi-flush mounting ECU-8 Controllers
- 1 Year warranty
- C-Tec EVC385 Voice Evacuation Alarms data sheet
£26.90 Inc VAT -
C-Tec EVC302F Voice Evacuation Alarms
- Flush mounted version
- Touch of a button communication
- Duplex operation
- High quality brushed stainless steel finish
- Includes connections for an optional induction loop system
- 1 year warranty
- C-Tec EVC302F Voice Evacuation Alarms user manual
- C-Tec EVC302F Voice Evacuation Alarms data sheet
£160.28 Inc VAT -
C-Tec ECU-4 Voice Evacuation Alarms
- Allows operators to communicate with the systems outstations
- Connects with 4 outstations
- Backlit LCD and handset
- Wall-Mounted
- Max 2x7Ah batteries
- 1 year warranty
- engineering manual
- quick start guide
- C-Tec ECU-4 Voice Evacuation Alarms user manual
- C-Tec ECU-4 Voice Evacuation Alarms data sheet
£790.53 Inc VAT -
C-Tec EVC302S Voice Evacuation Alarms
- Surface mounted version
- Touch of a button communication
- Duplex operation
- High quality brushed stainless steel finish
- Includes connections for an optional induction loop system
- 1 year warranty
- C-Tec EVC302S Voice Evacuation Alarms installation
- C-Tec EVC302S Voice Evacuation Alarms data sheet
£170.81 Inc VAT -
C-Tec EVC302GF Voice Evacuation Alarms
- Flush mounted version
- Touch of a button communication
- Duplex operation
- Finished in a tough, durable green steel
- Includes connections for an optional induction loop system
- 1 year warranty
- C-Tec EVC302GF Voice Evacuation Alarms instruction
- C-Tec EVC302GF Voice Evacuation Alarms data sheet
£145.11 Inc VAT