No products in the cart.
C-tec
C-tec was established in 1981. since then it grown into well reputed manufacturer in the UK. The company is well known for electronic safety products. Also, The electronic safety product like fire alarm, power supplies, automatic extinguisher, call system, hearing loop system and disabled refuge systems are part of the company portfolio. So, If you are in search for safety equipment. Then you have found the right place to have all what you need.
C-tec Fire Alarm
C-tec is well known for fire alarms system and it is the company speciality. it has gained over the decades experience. Many of its products are third party certified by reputed international test approval bodies. Such as the LPBC, the BSI, Intertek and the VdS, confirming to specifiers, installers and consumers. These bodies have rigorously tested our product for design and performance of Europe and British standards requirements.
If you need any professional advice or turnkey solution let us know. We will take care of your needs and provide turnkey solutions.
We at CCTV builder provide top notch products and C-tec is included in our portfolio. May it be the alarm systems, power supplies, call systems and any other C-tec specialized gadgets. Please feel free to reach us at [email protected]
-
C-Tec S-KEY Fire Control Panels
- Compatibility Suitable for use with C-TEC’s CFP 2-8 Zone Standard, Economy and AlarmSense fire panels, C-TEC’s XFP 1 Loop 16 Zone panel and C-TEC’s full range of ZFP multi-loop addressable fire panels.Product
- dimensions (mm)47 W x 25 H x 9 Dmm
- Construction & finish Red polycarbonate
- Weight 1g.
- For use with CFP main and repeater panels
- 1-year warranty
- DATA SHEET
£2.32 Inc VAT -
C-Tec BF375P Power Management
- Mains supply 230V 50/60Hz
- Output 250mA @ 21-28V DC.
- Indicators Mains On; Output Triggered.
- ControlsTrigger Release: requires +5-27V DC @ 5mA ; Hold Off (failsafe): requires a constant +5-27V DC @ 5mA; Local Trigger: Triggers when taken to 0V; Manual release via red button on PSU fascia.
- Connections Hold off; Trigger Release; Local Trigger; +V & 0V output.
- Product dimensions (mm)147 W x 87 H x 39 D mm.
- Construction & finish White PVC plate; Light grey label.
- IP Rating IP40.
- Weight 480g.
- Operating conditions/temperature -5ºC to +40ºC. Max relative humidity: 95%.
- 24V 250mA unregulated door release
- 1 Year Warranty
- Data sheet
£39.46 Inc VAT -
C-Tec SAF0724801 Fire Control Panels
- Cfp Accessory pack (inc resistors,capacitors and batery leads)
£7.71 Inc VAT -
C-Tec BF456A/CX/W Horn (Sounder)/Strobes (Beacons)
- Approvals/certifications Certified to EN54-3, 23 & 17 by the LPCB (0832-CPR-F1115).
- Protocol/compatibility Compatible with C-TEC’s XFP/ZFP XP95/Discovery Addressable Fire Panels.
- Application/operation Designed to be ceiling mounted – either stand-alone with a red or white cap or as part of a stacked Sounder/VAD/Detector Base combination.
- VAD category & coverage C-3-8 (15m3 cylindrical coverage).
- Flash rate & colour 0.5Hz / White.Supply/operating voltage17 to 28V DC (Sounder); 21 to 28V DC (Sounder/VAD).
- Quiescent current 550µA @ 24 VDC.
- Nominal SPL (Sound Pressure Level)96dB(A) when set to tone 1.
- Alarm current 14mA (VAD lit, Sounder on max).
- Indicators Polling (green LED) & Short Circuit Isolator Active (amber LED).
- Product dimensions (mm)122mm diameter x 46mm deep (not including optional XP95/Discovery detector and base).
- IP Rating IP21C (Type A).
- Weight 170g.
- Operating conditions/temperature-10ºC to +55ºC. Max. 95% RH (Non-condensing).
- 5 Year warranty.
- C-Tec BF456A/CX/W Horn (Sounder)/Strobes (Beacons) data sheet
£46.87 Inc VAT -
C-Tec CFP704-4 Fire Control Panels
- 4 Zone circuits
- Plastic lid and base
- 380 x 235 x 96mm
- 1 year warranty
- C-Tec CFP704-4 Fire Control Panels data sheet
£134.90 Inc VAT -
C-Tec EVC302GS Voice Evacuation Alarms
- Approvals/certifications Facilitate compliance with BS5839-9 when correctly installed
- Supply/operating voltage 11V DC derived from a compatible SigTEL Master Controller (drops to 6 V DC when in use).
- Quiescent current 3m AA ctivation current 25mA (current draw when intercom is in use).
- Open collector outputsO/P +Ve & O/P –Ve (closes when outstation is active, typically used to trigger a third party CCTV camera, opto-isolated, normally open, max. 24 V DC, 3 mA).
- Indicators Red call in progress LED Controls External ‘Push to Call or Answer’ button (Off Hook); Internal Loudspeaker volume control; Engineer’s “On Hook” and “Off Hook” pins.
- Expansion connections AFILS +Ve & AFILS –Ve (typically connected to the line-level input of an optional induction loop amplifier): Off-Hook and -Ve (can be optionally connected to an NC951 accessible toilet alarm kit (see instructions for details).
- Product dimensions (mm)160 W x 240 H x 53 D mm.Construction & finish Green steel.
- IP Rating IP20.
- Weight 1.3 kg.
- Operating conditions/temperature -5ºC to +40ºC. Max relative humidity: 95%.
- 1 year warranty
- C-Tec EVC302GS Voice Evacuation Alarms data sheet
£153.74 Inc VAT -
C-Tec BF451A/CX/SW Horn (Sounder)/Strobes (Beacons)
- Provides ‘C-3-8’ light distribution when ceiling mounted (min 0.4 lux over a 3 x 8m cylindrical area).
- Can also provide ‘W-3-3.1’ light distribution when wall mounted (min. 0.4 lux over a 3 x 3.1m cuboid area).
- Impressive 91dB(A) sound output @ 1m.
- 550µA quiescent current.
- 14mA alarm current @24Vdc (VAD lit, sounder on max).
- 7 selectable volume levels and up to 15 selectable tone pairs.
- EN54-23/3
- 5 Year warranty.
- C-Tec BF451A/CX/SW Horn (Sounder)/Strobes (Beacons) data sheet
£46.16 Inc VAT -
C-Tec BF433A/CX/DR Horn (Sounder)/Strobes (Beacons)
- Provides ‘W-2.4-8.2’ light distribution (min 0.4 lux over a 2.4m x8.2m cuboid area).
- Impressive 103dB(A) sound output @ 1m.
- 550µA quiescent current.
- 14mA alarm current @24Vdc (VAD lit, sounder on max).
- 7 selectable volume levels and up to 15 selectable tone pairs.
- Deep base
- EN54-3/23
- 5 Year warranty
- C-Tec BF433A/CX/DR Horn (Sounder)/Strobes (Beacons) data sheet
£57.62 Inc VAT -
C-Tec C4416 Conventional Detection
- Approvals/certifications Certified to EN54-7 by Intertek (0359-CPR-00183).Application/operationUses an IR light source & photodiode to detect smoke.
- Typically used in escape routes, living areas, bedrooms & other enclosed spaces. Particularly effective at detecting slow burning fires caused by overheated electrical wiring or smouldering materials.Application temperaturen/a.Static response temperaturen/a.
- Sensitivity Nominal alarm threshold of 0.16db/m obscuration measured in accordance with EN54-7:2000.
- Supply wiring 2-wire monitored, polarity sensitive.
- Supply/operating voltage 9 to 33V DC.
- Quiescent current 30µA @ 24 VDC.
- Alarm voltage 6-33V DC.
- Alarm current 19mA @ 12-33V DC; 11mA @ 9V DC; [email protected] 6V DC.
- Alarm reset voltage Less than 1V DC (+0.5 seconds alarm reset time).
- Expansion connections Remote LED output available via ActiV base.
- Current source to the negative line, short-circuit protected.
- Max voltage 2.7V DC.
- Product dimensions (mm)102.2mm diameter x 37mm deep (detector in base); 102.2mm diameter x 57.5mm deep.
- Construction & finish White polycarbonate casing rated to UL94 V-2 with nylon parts.
- IP Rating IP42.
- Weight 99g.
- 5 year warranty
- C-Tec C4416 Conventional Detection data sheet
£13.93 Inc VAT -
C-Tec XFP502/X Fire Control Panels
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
- 1 year warranty
- C-Tec XFP502/X Fire Control Panels data sheet
£730.00 Inc VAT -
C-Tec AFP711 Remote Annunciators/Repeaters
- for XFP 32 zone main panels
- One required per repeater system
- Fits at main panel
- An optional system expansion device for use with XFP 1/2 Loop 32 Zone fire panels.
- Allows the connection of up to eight XFP Repeaters or eight XFP Main panels (any mix) on an RS485 network.
- One AFP711 card required per networked Main XFP 1/2 Loop 32 Zone panel (note that XFP510-16 and XFP510-32 repeaters include a network driver card as standard).
- The AFP711 is NOT compatible with XFP Single Loop 16 Zone panels which require a CFP761 card for networking.
- 1 year warranty
- C-Tec AFP711 Remote Annunciators/Repeaters data sheet
£101.65 Inc VAT -
C-Tec ECU-8 Voice Evacuation Alarms
- Approvals/certifications Facilitate compliance with BS5839-9 when correctly installed
- Mains supply 230V 50/60Hz.
- Mains rated current500mA.
- Internal power supply 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).
- Total output current limited to1.5A @ 230Vac Quiescent current100mA (controller with fault buzzer sounding) plus 1mA per Type A outstation and 3.2mA per Type B outstation.
- Max battery size and type2 x 12V 7Ah VRLA connected in series.
- No. of lines8.Auxiliary relay changeover fault relay (failsafe). 30V 1A max
- Open collector outputs(OP1): Activates when the ECU is ringing; (OP2) Activates when there is an active accessible toilet alarm call; (OP3) Closes when the handset is off-hook and remains active for 2 mins after it is replaced. 24V, 50mA max.
- Other outputs +24 V.
- Typically used to supply power to equipment connected to the ECU’s open-collector outputs (relays, etc). Engineer (AL3) functions Engineer mode and reset buttons (internal).
- Indicators 128 x 64 pixel LCD display; Disablement; System fault; PSU fault; General fault; Power on.
- ControlsSilence Buzzer.
- Other controls are available but are not applicable as no handset is provided on this unit.
- Product dimensions (mm)410 W x 250 H x 80 D mm (base); 439 W x 274 H x 7 D mm (lid).
- Construction & finish metal lid and base, RAL7035 grey texture.
- IP Rating IP20.
- Weight 3.1kg (without batteries).
- Operating conditions/temperature-5ºC to +40ºC. Max relative humidity: 95%.
- 1 year warranty
- C-Tec ECU-8 Voice Evacuation Alarms data sheet
£1,007.53 Inc VAT -
C-Tec PL1/K3 Induction Loops
- With 1m (sq) portable loop amplifier and plug top charger.
- Ideal for restricted person to person contact
- Portable lightweight design
- Simple one button design means the system can be easily moved from location to location
- product dimension W 271 x H 200 x D 77mm (amplifier). Storage case measures: W 440 x H 370 x D 120mm.
- waight 2.82kg (amplifier only); 3.12Kg (case plus amplifier).
- IP rating IP20
- 12 months warranty
- C-Tec PL1/K3 Induction Loops data sheet
£235.35 Inc VAT -
C-Tec SAF7070000 Fire Control Panels
- 2m programming lead only
- 1 year warranty
- C-Tec SAF7070000 Fire Control Panels data sheet
£16.96 Inc VAT